The ROYALPROBE™ HFX is the world’s first liquid NMR probe switchable between single tune and dual tune mode on the High Frequency coil without compromising the NMR performance. The ROYALPROBE™ HFX operating in single tune mode has the performance for sensitivity and pulse width as the standard ROYALPROBE™. Operating the ROYALPROBE™ HFX in dual tune mode allows for a wide variety 1H and 19F of advanced NMR experiments including 1H{19F}, 19F{1H}, 13C{1H,19F}, and many unique 13C{1H, 19F} correlation experiments to simplify spectral assignments of modern complex fluorine containing compounds for the pharmaceutical and polymer industries. The Low Frequency coil is not limited to 13C, but can be tuned to any nucleus between 31P and 15N with the same experimental flexibility as 13C experiments a feature unique to the ROYALPROBE™ HFX.

Features

The JEOL ROYALPROBE™ HFX is the world’s first liquid NMR probe switchable between single tune and dual tune mode on the High Frequency coil without compromising the NMR performance.* The ROYALPROBE™ HFX operating in single tune mode has the same sensitivity and pulse width performance as the standard ROYALPROBE™.

Two probes merged into one

The JEOL ROYALPROBE™ HFX

Application examples of ROYALPROBE HFX -1-

Operating the ROYALPROBE™ HFX in dual tune mode allows for a wide variety 1H and 19F of advanced NMR experiments including 1H{19F}, 19F{1H},13C{1H,19F}, and many unique 13C{1H, 19F} correlation experiments to simplify spectral assignments of modern complex fluorine containing compounds for the pharmaceutical and polymer industries.
19F -NMR examples measured on a standard two RF channel JNM-ECZ500R

25mg, 1,1,2,3,3,3-Hexafluoropropyl ethyl ether / CDCl3 13C-NMR 256scans

Application examples of ROYALPROBE™ HFX -2-

2D 1H-13C HSQC with 19F decoupling, collected on a JEOL JNM-ECZ500R with optional HF2 19F 3rd channel

CRISIS-HSQCAD, 25% NUS 4scans

1H-13C gHMBCAD, 19F Decoupling Simplifies Assignments, 25% NUS, 8 Scans
10mg Fluticasone Propionate / DMSO-d6

Application examples of ROYALPROBE HFX -3-

The Low Frequency coil is not limited to 13C, but can be tuned to any nucleus between 31P and 15N with the same experimental flexibility as 13C experiments a feature unique to the ROYALPROBE™ HFX.
10mg, Decafluorotriphenyl Phosphine / CDCl3collected on a JEOL JNM-ECZ500R with optional HF2 19F 3rd channel

25mg 2,3-difluoro-5-(trifluoromethyl)pyridine /Benzene-d6 1H-15N HMBC 4scans

Application

Application ROYALPROBE_HFX

More Info

JEOL Instrument Basics

Easy explanation about mechanisms and
applications of JEOL products

Close
Notice

Are you a medical professional or personnel engaged in medical care?

Yes

No

Please be reminded that these pages are not intended to provide the general public with information about the products.

Contacts

JEOL provides a variety of support services to ensure that our customers can use our products with peace of mind.
Please feel free to contact us.