Superconducting magnets
(SCM)

Superconducting magnets (SCM)

The superconducting magnets(SCM) of the XC Series, JJ Series are compact, low helium-consumption magnets equipped with newly designed superconducting wires and cryostats.

Features

Superconducting magnets of XC Series(600MHz)

 

The superconducting magnets of the XC Series are named after the eXtreme Compact. The introduction of new superconducting wires and renewal of the coil design made it possible to largely reduce the magnet size compared with the conventional magnets while maintaining a high magnetic field evenness and magnetic field stability.

In consideration of the recent cost increase and short supply of liquid helium, the XC Series greatly improves the running cost due to newly designed cryostats with largely improved coolant evaporation speed.  Designed and developed in Japan, which is known as a country of frequent earthquakes,the magnets take over the robustness of magnets, which has been the key design policy of conventional magnets.

  • Not only the outer diameter and weight of magnets, but the ceiling height requirements are also reduced.

  • It is possible to place more than one NMR system close to the magnet.

  • The volume of refrigerant required for installation has been greatly reduced, and largely improves the running costs.

  • They are less susceptible to external magnetic field fluctuations

Superconducting magnets of JJ Series(400, 500, 700, 800 MHz)

The superconducting magnets of the JJ Series are compact, low helium-consumption magnets equipped with newly designed superconducting wires and cryostats.The JJ Series has a smaller footprint and lower ceiling height requirements than the previous products.

The consumption of liquid helium has been reduced and the filling interval has been extended. Similar to the XC Series, the JJ superconducting magnets are equipped with an extra coil that provides the highest level of isolation from fluctuations of external magnetic fields.  Therefore, even if the external magnetic field fluctuates, the magnetic field at the center of the magnet is virtually unaffected and extremely stable.

  • Smaller footprint and lower ceiling height requirements.

  • It is possible to place more than one NMR systems close to the magnet.

  • The filling interval of liquid helium has been extended.

  • They are less susceptible to external magnetic field fluctuations.

Space-saving design with a compact superconducting magnet

Greater flexibility of installation layout of the instrument is possible with the new compact magnets that have a smaller stray magnetic field

  • The installation space for the instrument is smaller and the minimum ceiling height is reduced

  • Possible to install several NMR instruments near each other

  • Longer time between liquid helium refills

 

400 MHz Year Hold Magnet (400JJYH)

Year Hold Magnet with greatly improved retention time of liquid helium

New 400 MHz Year Hold Super Conducting Magnet (400JJYH) has a greatly improved retention time of liquid helium while keeping its compact size as is. 400JJYH is a newly-developed magnet of reduced frequency of helium refill to once every year, while keeping cryostat compact. Newly-developed super conducting magnet has smaller stray magnetic field from the inside of the magnet to the outside. Combination with a compact spectrometer unit of ECZ NMR Spectrometer enables freer installation layout and placement of all units in a small area. In addition, as the design of the magnetic shield of SCM not only reduces the stray magnetic field, but also the influences from outside, installation of several NMR systems nearby is possible. It can offer a more reliable, safer, and comfortable use of the NMR system.

  • Refill frequency of liquid helium is now once a year

  • Compact size same as regular 400 MHz magnet

  • Freer layout of installation room

The magnets which can be available by cold shipment*

The superconducting magnets of JJ Series can be transported with liquid nitrogen or liquid helium in the cryostat, i.e., in a cooled state (cold shipment). In order to make cold-shipment possible, the strength of the composite reinforced rods that support the He and N2 vessels inside the SCM has been increased. These rods are designed to withstand the vibrations during transportation, and even large vibrations during earthquakes.

  • The transportation with liquid nitrogen or liquid helium is possible.

  • The internal structure is robust for vibration.

  • The cold shipment service is only available in Japan.

Earthquake-resistant magnets

JEOL's magnets comprise a highly reliable vibration isolator that has prevented SCMs from tipping over in major earthquakes in the past. The combination of the low center of gravity with the base plate and non-contact anchor bolts minimize damage in the event of a disaster.

Space-saving design with a compact superconducting magnet

Greater flexibility of installation layout of the instrument is possible with the new compact magnets that have a smaller stray magnetic field

  • The installation space for the instrument is smaller and the minimum ceiling height is reduced

  • Possible to install several NMR instruments near each other

  • Longer time between liquid helium refills

Related Products

Related Products

More Info

Science Basics

Easy explanation about mechanisms and
applications of JEOL products

Close
Notice

Are you a medical professional or personnel engaged in medical care?

Yes

No

Please be reminded that these pages are not intended to provide the general public with information about the products.

Contacts

JEOL provides a variety of support services to ensure that our customers can use our products with peace of mind.
Please feel free to contact us.