【DISCONTINUED】JPS-9010 Photoelectron Spectrometer

DISCONTINUED

JPS-9010 Photoelectron Spectrometer

This product is no longer available.

If you would like to know the latest information about your preferred product or to find out more about alternatives, please click on the link below. We hope you will continue to use our products.

A well-balanced multifunction photoelectron spectrometer equipped with high-speed etching gun and twin anode monochromator, which also realizes low cost.

Features

Kauffmann Type Ion Gun

A high-speed ion gun enabling etching of 10 mm areas at a rate of up to 120 nm/min.  The performance, which is superior to ion milling, can fulfill various objectives, from surface cleansing to depth.

Pan Focus Input Len System

A high-operability system has been realized without analyzer-unique complicated operations, such as specimen positioning and adjustment of the electron optics system.

Data analysis software for surface analysis

Besides our conventional waveform separation method, new waveform separation algorithms using the actual spectrum and utilizing the standard spectrum library of XPS and AES have been incorporated.  This frees operators from complicated parameter settings that require experience and expertise, making it possible for even a novice to carry out complicated chemical bonding state analysis.

Specifications

Sensitivity and resolution
Ag3d5/2 photoelectron measured on a clean and flat Ag sample
Standard  X-ray source(equivalent to 300W MgKαexcitation)
Sensitivity(cps) Resolution(eV)
540,000 0.90
1,800,000 1.15
5,000,000 1.8
Monochromatic X-ray source(equivalent to 600W AlKα excitation)
Sensitivity(cps) 65,000
Resolution(eV) 0.65
X-ray source
Standard X-ray source (Al/Mg twin target)
Maximum power Mg 500W
Al 600W
Energy analyzer and incident lens system
Incident lens 3-step cylindrical electrostatic lens
Energy sweep system Constant  analyzer energy method
Vacuum evacuation system
Ultimate pressure 7×10-8Pa or less
Bakeout mechanism Inner heater built-in, automatic control

Application

Application JPS-9010series

More Info

JEOL Instrument Basics

Easy explanation about mechanisms and
applications of JEOL products

Close
Notice

Are you a medical professional or personnel engaged in medical care?

Yes

No

Please be reminded that these pages are not intended to provide the general public with information about the products.

Contacts

JEOL provides a variety of support services to ensure that our customers can use our products with peace of mind.
Please feel free to contact us.