Close Btn

Select Your Regional site

Close

SEM-EDS Fundamentals: Tips for Reliable Elemental Analysis

Release Date: 2026/07/08

When conducting failure analysis or observing foreign materials, SEM-EDS is a powerful method, enabling simultaneous microstructure characterization and elemental analysis. This webinar explains the theory behind optimizing measurement conditions such as accelerating voltage, probe current, and acquisition time to obtain reliable data, using several practical examples.

This seminar will be delivered online in an on-demand format, available for a limited time. Enjoy the flexibility to view the content anytime, anywhere during the designated period.

By attending this webinar you will learn…

  • Optimal conditions for EDS analysis such as accelerating voltage, probe current, and acquisition time

  • Tips for EDS analysis using practical examples

  • Useful features of JEOL’s EDS system

Who should attend?

  • Those who are new to elemental analysis

  • Those looking to optimize EDS measurement conditions

  • Analytical service providers

Related Products

JSM-IT210 Scanning Electron Microscope

JSM-IT510 InTouchScope™ Scanning Electron Microscope

JSM-IT710HR Scanning Electron Microscope

JCM-7000 NeoScope™ Benchtop SEM

Presenter

Takayuki Hirai

EP Application Department
EP Business Unit
SI Business Operations
JEOL Ltd.

Kazuki Watanabe*
* Speaker

EP Application Department
EP Business Unit
SI Business Operations
JEOL Ltd.

On-Demand Viewing Period

Oct 21 (Wed) to Oct 23 (Fri), 2026

  • Please note that the dates are based on Japan Standard Time (JST). Kindly check your local time zone when accessing the content.

Fee

Free

Presentation Materials

You can download these materials after completing the post-presentation survey.

Recording

The recording of the webinar will be posted on the "Webinar Archive" page at a later date.
We will notify you via our e-newsletter and social media once it becomes available.

Q&A Session

There will be no Q&A session following the presentation.

Contacts

E-mail:sales1[at]jeol.co.jp
Demand Generation Div.
JEOL Ltd.

  • please use @ for [at]

Registration

Please register here.

  • For those who have registered, we will send you information on how to access the video viewing page approximately approximately the previous weekend before the scheduled start date. We kindly ask for your patience until then.
  • Please note that we may not be able to accept registrations from other companies in the same industry.
Close
Notice

Are you a medical professional or personnel engaged in medical care?

Yes

No

Please be reminded that these pages are not intended to provide the general public with information about the products.