High-power electron beam sources

JEBG series High-power electron beam sources

High-power electron beam sources for vacuum evaporation of metals and metal-oxides to a wide plastic film or a large glass plate that are continuously fed. And also used for vacuum melting of high-melting point metals.

Features

Electron beam can be swept a wide area at high speed. Various beam irradiation patterns and areas can be created by dedicated control device and software. Sweeping, dwell time, output power and beam shape at each irradiation position can be set up individually, thus can control melting surface and film thickness distribution.

Applications

Vacuum deposition

Gas barrier films, protective films, electrode films, conductive films, magnetic storage films.

Vacuum melting

Refinement/Ingot production of high-melting-point metals such as Ti, Ta, Nb and Mo.
Polycrystalline silicon refining for solar cell.

High-power electron beam source

Click the "replay" button in the box above, and the movie will start (for 1 minute)

  • This movie includes some light flashing moments.
    Watching the movie may affect you physically, such as attack/stroke or may make you feel bad.
    When you watch it, please keep a reasonable distance from the movie in a bright room. Your careful attention is appreciated.

2 line scanning

Click the "replay" button in the box above, and the movie will start (for 1 minute)

  • This movie includes some light flashing moments.
    Watching the movie may affect you physically, such as attack/stroke or may make you feel bad.
    When you watch it, please keep a reasonable distance from the movie in a bright room. Your careful attention is appreciated.

Specifications

Model EBG-300UA JEBG-1000UB JEBG-3000UB
Maximum output 30kW
(20kV, 1.5A)
100kW
(30kV, 3.4A)
300kW
(40kV, 7.5A)
Beam deflection angle Max. ±30°
Sweeping direction X, Y axis
Maximum sweeping frequency 300Hz 200Hz 200Hz
(300Hz: Option)
Corresponding power supply ST-30BE2 JST-100C JST-300CHR

Catalogue Download

Application

Application JEBGseries

More Info

JEOL Instrument Basics

Easy explanation about mechanisms and
applications of JEOL products

Close
Notice

Are you a medical professional or personnel engaged in medical care?

Yes

No

Please be reminded that these pages are not intended to provide the general public with information about the products.

Contacts

JEOL provides a variety of support services to ensure that our customers can use our products with peace of mind.
Please feel free to contact us.