JMS-S3000 SpiralTOF™ series Shared Instrument Applications Notebook
Edition May 2026
This is an application notebook that summaries a wide variety of applications of the JMS-S3000 SpiralTOF™ series MALDI-TOFMS that are useful as a shared instrument at universities.
Please see the PDF file for the additional information.
Another window opens when you click.
Table of Contents
JMS-S3000 NewSpiralTOF™ MALDI-TOFMS as a Shared Instrument P1〜
Organic Chemistry P3〜
- Accurate mass measurement of small molecules: Analysis of medicinal properties in a combination cold remedy by using JMS-S3000 “SpiralTOF™” (MSTips No. 241)
- Accurate mass measurement of a large molecule: Measurement of boroxine cage using JMS-S3000 “SpiralTOF™” (MSTips No. 369)
- Structural analysis of a small molecule: Structural analysis of a small molecule using JMS-S3000 “SpiralTOF™-plus 2.0”ーMS/MS measurement of a photodegradation product of reserpineー (MSTips No. 365)
Polymers / Oligomers / Surfactants P9〜
- Molecular weight distributions of high molecular weight polymers: Analysis of high molecular weight polystyrene standards by using JMS-S3000 "SpiralTOF™" with Linear TOF option (MSTips No. 199)
- Analysis of anionic surfactants in negative ion detection mode: Structural analysis of anionic surfactants in MALDI negative ion mode using "SpiralTOF™-plus" (MSTips No. 333)
- Analysis of an insoluble polymer with solvent-free method: Analysis of low molecular weight polyethylene with solvent-free method using JMS-S3000 "SpiralTOF™" (MSTips No. 235)
Proteins / Peptides P15〜
- Molecular weight measurement of proteins: High Sensitivity Analysis of Intact Proteins Using Linear TOF (MSTips No. 227)
- Identification of a protein with peptide mass fingerprinting (PMF) method: Analysis of Bovine Serum Albumin (MSTips No. 166)
- Identification of a protein with MS/MS ion search method: High-Energy CID Analysis of Bovine Serum Albumin (MSTips No. 174)
- Amino acid sequence analysis of a peptide: Structural Analysis of a High Molecular Weight Peptide (MSTips No. 175)
- Amino acid sequence analysis by using In-source Decay (ISD) method: MALDI-ISD Measurements Using Both the SpiralTOF™ Mode and the Linear Mode (MSTips No. 229)
Lipids P25〜
- Structural analysis of phospholipids: Structural analysis of phospholipids in egg yolk using JMS-S3000 “SpiralTOF™” with TOF-TOF option (MSTips No. 185)
Nucleic Acids P27〜
- Accurate mass measurement of a synthetic nucleic acid: Analysis of oligonucleotides using JMS-S3000 "SpiralTOF™-plus 2.0" (MSTips No. 364)
Oligosaccharides P29〜
- Structural analysis of N-linked glycan: Structural analysis of N-linked glycan (MSTips No. 519)
Natural Products P31〜
- Structural analysis of a natural product: Analysis of the Natural Organic Compound YTX by Using the TOF-TOF Option
Mass Spectrometry Imaging P33〜
- High mass-resolution MS imaging of lipids in a mouse brain section: Phase analysis of mass spectrometry imaging data using high-resolution MALDI-TOFMS “NewSpiralTOF™” and vertex component analysis (MSTips No. 528)
- High mass-resolution MS imaging of lipids in a mouse brain section: Mass image quality improvement using a machine learning model “FINE-AI Filter” (MSTips No. 526)
- MS imaging of a strawberry fruit: Mass imaging of strawberry using the JMS-S3000 “SpiralTOF™-plus3.0” and transfer plate Poropare™ (MSTips No. 499)
Solutions by field
Related products