JMS-S3000 SpiralTOF™ series Imaging Applications Notebook

Edition August 2023

This is a compendium of mass spectrometry imaging applications notes and JEOL News articles based on the data acquired on JEOL ultra-high mass-resolution MALDI-TOFMS JMS-S3000 SpiralTOF™ series.

Please see the PDF file for the additional information.
Another window opens when you click.

Table of Contents

Introduction and Fundamentals P1~

  • Mass Spectrometry Imaging using the JMS-S3000 "SpiralTOF™-plus" Matrix Assisted Laser Desorption Ionization Time-of-Flight Mass Spectrometer (Takaya Satoh, JEOL News, 55, 70-72, 2020)

  • Development of JMS-S3000: MALDI-TOF/TOF Utilizing a Spiral Ion Trajectory (Takaya Satoh, JEOL News, 45, 34-37, 2010)

  • High Mass Resolution MALDI-Imaging MS – High Stability of Peak Position during Imaging MS Measurement (MSTips No. 193)

  • The Relationship between Crystal Condition and Mass Resolving Power, Mass Accuracy (MSTips No.206)

Life Science / Biomolecules P17〜

  • High mass-resolution MS imaging using JMS-S3000 "SpiralTOF™" and statistical data analysis (MSTips No. 370)

  • High Mass-Resolution MALDI-imaging MS for Drug Metabolism in Tissue Using the JMS-S3000 (MSTips No. 212)

  • High Mass Resolution MALDI-imaging MS Using JMS-S3000 SpiralTOF™ and msMicroImager (MSTips No. 211)

  • Fingerprint Analyses Using MALDI Imaging and SEM Imaging (MSTips No. 208)

  • MALDI-Imaging MS of Lipids on Mouse Brain Tissue Sections Using Negative Ion Mode (MSTips No. 196)

Polymers / Materials P35〜

  • Degradation analysis of polyethylene terephthalate film by UV irradiation using imaging mass spectrometry and scanning electron microscopy (HS05)

  • Mass spectrometry imaging for degradation of polyethylene terephthalate by UV irradiation using JMS-S3000 "SpiralTOF™-plus" (MSTips No. 307)

  • A mass spectrometry imaging method for visualizing synthetic polymers combined with Kendrick mass defect analysis (MSTips No. 306)

  • A mass spectrometry imaging method for visualizing synthetic polymers by using average molecular weight and polydispersity as indices. (MSTips No. 305)

  • Mass spectrometry imaging on mixed conductive/non-conductive substrate using JMS-S3000 SpiralTOF™ (MSTips No. 288)

  • Analysis of organic compounds on an acrylic plate using JMS-S3000 "SpiralTOF™" (MSTips No. 251)

  • Ballpoint Ink Analyses Using LDI Imaging and SEM/EDS Techniques (MSTips No. 204)

  • Gunshot Residues (GSR) Analysis by Using MALDI Imaging

  • Analysis of Organic Thin Films by the Laser Desorption/Ionization Method Using the JMS-S3000 "SpiralTOF™" (Satoh, T., JEOL News, 49, 81-88, 2014)

Solutions by field

Related products

Close
Notice

Are you a medical professional or personnel engaged in medical care?

Yes

No

Please be reminded that these pages are not intended to provide the general public with information about the products.

JEOL Instrument Basics

Easy explanation about mechanisms and
applications of JEOL products

Contacts

JEOL provides a variety of support services to ensure that our customers can use our products with peace of mind.
Please feel free to contact us.