AccuTOF™ GC series Petroleum and Petrochemicals Applications Notebook
Edition February 2023
Edition February 2023
This is a compendium of petroleum and petrochemicals related applications notes and JEOL News articles based on the data acquired on JEOL high resolution GC-TOFMS AccuTOF™ GC series (JMS-T100GC, JMS-T100GCV, JMS-T200GC, and JMS-T2000GC).
Please see the PDF file for the additional information.
Another window opens when you click.
Table of Contents
Introduction P1~
MultiAnalyzer – Unknown Compounds Analysis System
New Gas Chromatograph – Time-of-Flight Mass Spectrometer JMS-T2000GC "AccuTOF™ GC-Alpha"
(Ubukata, M., JEOL news, 56, 66 – 72, 2021)Introduction of AI Structure Analysis Function in Automatic Structure Analysis Software msFineAnalysis AI (MSTips No. 388)
JMS-T2000GC AccuTOF™ GC-Alpha Sensitivity in nitrogen carrier gas ① - EI / PI ion source (MSTips No. 374)
JMS-T2000GC AccuTOF™ GC-Alpha Sensitivity in nitrogen carrier gas ② - EI / FI ion source (MSTips No. 375)
JMS-T2000GC AccuTOF™ GC-Alpha Sensitivity in nitrogen carrier gas ③ - CI ion source (MSTips No. 376)
Effect of JMS-T2000GC high mass resolution on the analysis result -KMD Plot comparison using msRepeatFinder- (MSTips No. 332)
Effect of high mass accuracy on the analysis result by JMS-T2000GC -Effect to narrow down the result of msFineAnalysis integrated analysis- (MSTips No. 331)
Development of an Integrated Analysis Method for the JMS-T200GC High Mass-Resolution GC-TOFMS by Electron Ionization and Soft Ionization Methods
(Ubukata, M., Ueda, Y., JEOL news, 50, 83 – 89, 2019)Comparison of performance between PI and FI by using GC-HRTOFMS
High-speed 50 Hz Data Acquisition Capability for Comprehensive 2-dimensional GC Measurements (MSTips No. 226)
The Qualitative Analysis of an Antioxidant Additive Using the Full Capabilities of the EI/FI/FD Combination Ion Source (MSTips No. 224)
GC/MS, GCxGC/MS P49~
Biomarker Analysis in Petroleum Samples Using GC×GC-HRTOFMS with an Ion Source
Combining Electron Ionization (EI) and Photo Ionization (PI)
(Ubukata, M., Ueda, Y., JEOL news, 53, 54 – 58, 2018)GCxGC TOFMS Analysis of Base Oils with CI, PI, FI (MSTips No. 285)
Diesel Fuel Classification Analysis Using GC x GC/FI and Kendrick Mass Defect Plots
GC x GC/EI and GC x GC/FI Measurements Using the EI/FI Combination Ion Source (MSTips No. 225)
Analysis of diesel oil by using GC x GC-HRTOFMS (FI) with 2 different sets of column combinations (MSTips No. 154)
Accurate mass measurement of lube oil by GC/FI-TOFMS (MSTips No. 058)
Qualitative analysis by comprehensive 2D GC / TOFMS [1] - Comparison of kerosene and diesel oil – (MSTips No. 055)
Qualitative analysis by comprehensive 2D GC / TOFMS [2] - Analysis of polycyclic aromatic hydrocarbons in kerosene – (MSTips No. 056)
Qualitative analysis by comprehensive 2D GC / TOFMS [3] - Analysis of sulfur-contained substances in diesel oil – (MSTips No. 057)
Group-Type Analysis P75~
Rapid analysis using inactivated fused silica tube (a.k.a. "guard column") as a sample inlet (1) (MSTips No. 111)
Rapid analysis using inactivated fused silica tube (a.k.a. "guard column") as a sample inlet (2) (MSTips No. 112)
Type Analysis of Micro Crystalline Wax (Petroleum Wax) (MSTips No. 100)
Degradation of rotary vacuum pump oil determined by field desorption (FD) - TOFMS and group-type analysis software (MSTips No. 098)
Group-type analysis of Crude Oil using GC/FI-TOFMS 1 ~Determination of average molecular weights by group-type analysis~ (MSTips No. 071)
Group-type analysis of Crude Oil using GC/FI-TOFMS 2 ~Reproducibility of group-type analysis results~ (MSTips No. 072)
Direct Sample Introduction (Direct Probes, Field Desorption) P87~
Additive analysis in lubricating oil by FD method using JMS-T2000GC AccuTOF™ GC-Alpha (MSTips No. 356)