AccuTOF™ GC series Petroleum and Petrochemicals Applications Notebook

Edition February 2026

Over 100 pages of GC/TOFMS applications for petroleum and petrochemical analysis

Catalogue Download

Overview

Welcome to the AccuTOF™ GC series Petroleum & Petrochemicals Applications Notebook. This edition brings together practical application notes demonstrating how GC‑TOFMS enables confident characterization of complex hydrocarbon mixtures—supporting tasks from rapid screening and group‑type analysis to detailed identification of trace heteroatom species and additives.
Throughout the notebook, you will see how the JMS‑T2000GC platform and msFineAnalysis AI streamline both targeted and non‑targeted workflows by combining hard/soft ionization (EI with FI/PI/CI), Kendrick Mass Defect (KMD) interpretation, and GC×GC data analysis for deeper compositional insight. We hope these examples—spanning crude oil, diesel, base oils, waxes, and recycling‑derived pyrolysis oils—serve as a practical reference to accelerate method development, strengthen QC, and broaden analytical capability in petroleum and petrochemical research.

Recommended for

  • Petroleum and petrochemical analysts working with crude oil, diesel, and base oils
  • Users needing EI/FI/FD and GC×GC‑TOFMS for complex hydrocarbon analysis
  • Researchers performing KMD or group‑type analysis of heavy petroleum fractions
  • Chemists analyzing additives, degradation products, or pyrolysis oils
  • Labs requiring high‑resolution, high‑accuracy GC/TOFMS for non‑targeted workflows

Table of Contents

Combination of multiple sample introduction techniques P1~

  • Rapid analysis of pyrolysis oil using blank tube-FI method and GC-EI/FI method of JMS-T2000GC (MSTips No. 468)
  • Multifaceted crude oil analysis using GC-EI/FI, blank tube-FI, and FD on JMS-T2000GC (MSTips No. 452)

GCxGC/MS P9~

  • GCxGC data analysis of msFineAnalysis AI Ver. 3 ①Diesel fuel (MSTips No. 509)
  • GCxGC data analysis of msFineAnalysis AI Ver. 3 ③Pyrolysis oil (MSTips No. 511)
  • Biomarker Analysis in Petroleum Samples Using GCxGC-HRTOFMS with an Ion Source Combining Electron Ionization (EI) and Photo Ionization (PI) (Ubukata, M., Ueda, Y., JEOL news, 53, 54 - 58, 2018)
  • GCxGC TOFMS Analysis of Base Oils with CI, PI, FI (MSTips No. 285)
  • Diesel Fuel Classification Analysis Using GC x GC/FI and Kendrick Mass Defect Plots
  • GC x GC/EI and GC x GC/FI Measurements Using the EI/FI Combination Ion Source (MSTips No. 225)
  • Analysis of diesel oil by using GC x GC-HRTOFMS (FI) with 2 different sets of column combinations (MSTips No. 154)

GC/MS P35~

  • Qualitative Analysis of Catalytic Reaction Products using msFineAnalysis AI - Upcycling of Discarded Polystyrene - (MSTips No. 456)
  • Accurate mass measurement of lube oil by GC/FI-TOFMS (MSTips No. 058)

Group-Type Analysis P41~

  • Rapid analysis using inactivated fused silica tube (a.k.a. “guard column”) as a sample inlet (1) (MSTips No. 111)
  • Rapid analysis using inactivated fused silica tube (a.k.a. “guard column”) as a sample inlet (2) (MSTips No. 112)
  • Type Analysis of Micro Crystalline Wax (Petroleum Wax) (MSTips No. 100)
  • Degradation of rotary vacuum pump oil determined by field desorption (FD) - TOFMS and group-type analysis software (MSTips No. 098)
  • Group-type analysis of Crude Oil using GC/FI-TOFMS 1 ~Determination of average molecular weights by group-type analysis~ (MSTips No. 071)
  • Group-type analysis of Crude Oil using GC/FI-TOFMS 2 ~Reproducibility of group-type analysis results~ (MSTips No. 072)

Direct Sample Introduction (Direct Probes, Field Desorption) P53~

  • Additive analysis in lubricating oil by FD method using JMS-T2000GC AccuTOF™ GC-Alpha (MSTips No. 356)

Details of the hardware and software P55~

  • msFineAnalysis AI Novel Qualitative Analysis Software for JMS-T2000GC with AI Structural Analysis (Kubo, A., JEOL news, 58, 53 - 61, 2023) (MSTips No. 388)
  • MultiAnalyzer - Unknown Compounds Analysis System New Gas Chromatograph - Time-of-Flight Mass Spectrometer JMS-T2000GC "AccuTOF™ GC-Alpha" (Ubukata, M., JEOL news, 56, 66 - 72, 2021)
  • Development of an Integrated Analysis Method for the JMS-T200GC High Mass-Resolution GC-TOFMS by Electron Ionization and Soft Ionization Methods (Ubukata, M., Ueda, Y., JEOL news, 50, 83 - 89, 2019)
  • Improving the Sensitivity of GC/FI Measurements with a New FI Emitter (MSTips No. 476)
  • Introduction of AI Structure Analysis Function in Automatic Structure Analysis Software msFineAnalysis AI (MSTips No. 388)
  • JMS-T2000GC AccuTOF™ GC-Alpha Sensitivity in nitrogen carrier gas ① - EI / PI ion source (MSTips No. 374)
  • JMS-T2000GC AccuTOF™ GC-Alpha Sensitivity in nitrogen carrier gas ② - EI / FI ion source (MSTips No. 375)
  • JMS-T2000GC AccuTOF™ GC-Alpha Sensitivity in nitrogen carrier gas ③ - CI ion source (MSTips No. 376)
  • Effect of JMS-T2000GC high mass resolution on the analysis result - KMD Plot comparison using msRepeatFinder - (MSTips No. 332)
  • Effect of high mass accuracy on the analysis result by JMS-T2000GC - Effect to narrow down the result of msFineAnalysis integrated analysis - (MSTips No. 331)

Contact

For any question or inquiry regarding this Applications Notebook, please contact your local JEOL representative, or use the Product Information Request form on our Global Web Site.

Solutions by field

Related products

JMS-T2000GC AccuTOF™ GC-Alpha 2.0 Gas Chromatograph - Time-of-Flight Mass Spectrometer

msFineAnalysis AI Unknown Compounds Structure Analysis Software

msRepeatFinder Polymer Analysis Software

Close
Notice

Are you a medical professional or personnel engaged in medical care?

Yes

No

Please be reminded that these pages are not intended to provide the general public with information about the products.

JEOL Instrument Basics

Easy explanation about mechanisms and
applications of JEOL products

Contacts

JEOL provides a variety of support services to ensure that our customers can use our products with peace of mind.
Please feel free to contact us.