Institute for Materials Chemistry and Engineering (IMCE), Kyushu Univ.

From liquid crystals to blue carbon
Our NMR measurements welcome any sample that comes our way

Kyushu University's Institute for Materials Chemistry and Engineering (IMCE) has been promoting research ranging from fundamental science to practical applications and social implementation, with the aim of generating world-leading achievements in the interdisciplinary field of materials chemistry. As a Joint Usage/Research Center, the institute is committed to advancing cutting-edge and interdisciplinary collaborative research in the fields of materials and devices. The Center for Materials Properties and Function Evaluation within the institute houses a concentration of large-scale shared-use instruments, ensuring their optimal utilization. The center is also staffed by a team of technical specialists who provide training in measurement techniques and analytical methods for students within the institute. In addition, they offer technical consultation on advanced measurements and conduct commissioned analyses for academic researchers both inside and outside the institute and companies. We interviewed Keiko Ideta, a technical staff member who collaborates with researchers both inside and outside the institute, about her work and experiences.

Institute for Materials Chemistry and Engineering

Activities of the center

Could you tell us about the organization of the Evaluation Center of Materials Properties and Function and your day-to-day responsibilities?

Our Center has five technical staff members, and each one is primarily responsible for the management and operation of specific analytical instruments. Our main duties include keeping these instruments in optimal working conditions, consulting with users on their analytical needs, and conducting measurements, as well as training users to properly operate the equipment. I am mainly responsible for seven NMR spectrometers and one ESR spectrometer.
Another important part of our work is contributing to the specification process when analytical instruments are upgraded or replaced. We incorporate comments from users and operators in the field, such as "it would be great to have this function" or "we would like this aspect to be more user-friendly."

Where do measurement requests come from, and how are they submitted?

The majority comes from within the IMCE, followed by requests from other departments in Kyushu University and then from external organizations. We also receive a significant number of requests from industries.
Typically, inquiries are first submitted through the Evaluation Center of Materials Properties and Function's web form or by email. We then discuss the details of the requested measurements, sample delivery, and payment arrangements with the client before formally accepting the project and carrying out the measurements.

How do you select instrument from as many as seven NMR spectrometers?

The center is equipped with 800 MHz, 600 MHz, 400 MHz, and 300 MHz NMR spectrometers, offering a variety of probes and measurement methods. Although they have the same name, NMR, each of them has its own difference. Therefore, we consult with users about the conditions of their samples, what they wish to investigate, and their budget and work together to select the most appropriate measurement method and instrument.
Sometimes we are asked "Why don't you use 800 MHz since you have it?". However, once we discuss the details of the measurement, we often find ourselves recommending "It is better to use 400 MHz.", which is often the case. Of course, for an inorganic nuclei such as aluminum, we recommend 800 MHz as it achieves sharper peaks and higher resolution.
In addition, while measuring solutions can sometimes be done in just a few minutes, measuring solids can take a week--the time scales are completely different, so we really do need this many.

Points to note for NMR measurements

What information should users provide in advance?

As the minimum information, whether the state of the sample is a solution or a solid? And what nuclei the requestor wants to measure? We would like to know those. Surprisingly, quite a few people bring in samples without saying a word.
It is partly to ensure that measurements proceed smoothly. But, since users incur costs when requesting measurements, we also want to estimate the equipment and time required as accurately as possible and communicate this information to them. While I can't give them a definitive answer right there during the consultation, I can give them a rough estimate based on these assumptions.
Other than this, if an abundance ratio of elements is needed, we need to select a suitable measurement method. So, we want to know that beforehand. It's a bit of a hassle when someone brings in a sample, we run the standard test, and then they say, "I came here to find out the abundance ratio!" While it has become less common lately, it's a classic student thing (wry smile).

I hear you even offer advice on analytical methods?

Since some people come in for measurements without knowing exactly what their goal is, I sometimes offer advice--such as suggesting that they clarify their objectives a bit more or that they might benefit from combining NMR and MS--, while discussing their needs with them. In the case of students in the institute, we can understand their idea of research roughly once the laboratory they belong to is known. So, sometimes we give information from our end and send related papers on how to prepare samples.

Who will perform the measurement?

We instruct students and teachers who use instruments frequently, so they can perform measurements by themselves. For example, researchers in organic synthesis field perform solution measurements more than once every day and it is important for them to perform measurements as soon as they want to measure. However, in case of a specific measurement, we often perform the measurement together with them.

NMR TOPICS

We've started NMR measurements of liquid crystals!

I started NMR measurements of liquid crystals around a year ago, due to a consultation from a professor in our university. Personally, I find liquid crystals to be a very interesting objective for measurement, different from solutions and solid. Practically, we first pack the samples in a powder state in the sample tube for liquid, load the sample tube into the NMR instrument, and then heat it so that the sample powders will become liquid crystal. When I presented the spectra I actually obtained at NMR conferences, everyone had a look on their faces saying "I have not seen anything like this often!". Going forward, I will work on the measurement of ferroelectric liquid crystals, which are the focus of research conducted by a professor in the institute.

19F-NMR spectra of a liquid crystal molecule exhibiting a ferroelectric nematic phase.

Exploring research on blue carbons!

Recently, a research has been underway in Professor Miyawaki's laboratory here to use marine biomass--such as Wakame and Kombu, collectively known as "blue carbon"--as a raw material for carbon-based materials like activated carbon and electrodes. I also participate in research whenever I can find the time, while helping out with the NMR measurement.
If you want to produce activated carbon using terrestrial biomass (green carbons) such as wood, activation processes to heat the raw materials and introduce narrow holes to the heated and carbonized material using chemicals are required, which needs significant amount of energy. On the other hand, in the case of marine biomass, which is rich in minerals, simply washing and removing the minerals after carbonization yields a porous carbon material with a large number of externally accessible pores, thereby simplifying the manufacturing process.

We measured the 13C and 23Na NMR spectra of marine biomass during the carbonization process via heat treatment. Our results showed that washing with water after carbonization at 600°C yields porous carbon, and that washing with carbonated water after carbonization at 900°C yields porous carbon with a high specific surface area of approximately 1,200 m2/g--even without an activation process.
I would like to continue these measurements and research on marine biomass in the future.

Photo with Associate Professor Miyawaki in Institute for Materials Chemistry and Engineering

Doctoral degree obtained through long-term research

What inspired you to begin the research that eventually led you to your doctoral degree?

The starting point was the solution NMR measurement of a sample derived from coal and petroleum, per the request of a professor in the institute 20 years ago. Until that time, I only knew solution NMR measurements of purified samples, so I couldn't expect the result of the black sample I was handed over at all.Is it possible to analyze the sample? What research project is the laboratory working on? I became curious about the samples that were new to me. After that, I started attending the seminars of the laboratory and I continued participating in the seminar of Associate Professor Miyawaki.

What was your research theme for your doctoral dissertation?

Roughly speaking, it was about research on electric double layer capacitors (EDLCs) using solid-state 19F NMR.
For EDLC electrode, porous carbons with a large specific surface area are used. There are many choices for raw materials and the earlier-mentioned sample derived from coal and petroleum was one of them. This NMR measurement made me begin researching EDLC, and I chose phenol resin as raw material, produced electrodes made of porous carbon which had various specific surface area and pore size, performed actual charging and discharging, and conducted NMR measurement of the electrode before and after the charging and discharging. As a result, it became clear that porous carbon with mesopores (2-50 nm) was suitable for operating EDLC (the diffusion resistance of electrolyte ions is small, enabling high speed charging and discharging). I made this result into my doctoral dissertation.
Through the research after that, an advantage of marine biomass was found to have mesopores without activation process.

Are there many technical staff members who obtain doctoral degrees?

It depends on the environment. It is relatively easy to explore one theme if you belong to a laboratory as before. However, recently, technical staff members have been organized across the university, it may be difficult. Fortunately, the professors around me were understanding and consistently provided guidance and advice, which enabled me to continue my research.

In front of NMR (600MHz) with a technical staff, Ms. Imamura.

I count on you, JEOL-san!!

When I recall, all of my skills in performing NMR measurement relied on JEOL engineers.
The service engineers who handle daily maintenance and trouble are working in the institute as often as the employees of the university (laughter). When I was assigned to this institute, I always followed JEOL service engineers who frequently visited the institute as I did not know anything.
And as it comes to measurement, I consulted with a JEOL application staff and learned a lot. Even now, if I need to do something new with the NMR spectrometers, I always consult with the application people.
For example, when I brought the idea of measuring liquid crystals to them, they created measurement programs promptly and made adjustments based on measurement results, which was a great help.
I truly count on JEOL people. I appreciate their continued support.

Keiko Ideta

Evaluation Center of Materials Properties and Function, Institute for Materials Chemistry and Engineering, Kyushu University

After graduating from the Department of Applied Chemistry, Faculty of Engineering, Kyushu University, she has held the current position since 2001 after she worked as a technical staff in the School of Computer Science and Systems Engineering, Kyushu Institute of Technology, Kyushu Institute of Technology. She holds a Ph.D. in Engineering.

-Comments from a researcher-
We are focusing on blue carbon!

Our laboratory has been primarily exploring carbon materials, and Ideta-san provides us with detailed and attentive support for NMR measurements. Although our students learn to perform NMR measurements themselves with her proper guidance, in order to further understand and elucidate reaction mechanism, the analytical expertise of Ideta-san is inevitable. In addition, I was also involved in her research of electric double layer capacitors, and I believe that her persistently built-up research results culminated in an excellent doctoral dissertation.

Talking about the future research activities, the world is moving toward sustainable and carbon-neutral directions. In such age, the researchers working on carbon materials like us are trying to apply our knowledge and skills of fossil resources into biomass, which is sustainable resources. While biomass on land is widely used, we are recently interested in marine biomass, taking Japan's geographical characteristics into account. Marine biomass grows rapidly and absorbs in (fixes) more carbon dioxides before harvest than the biomass on land. Moreover, ocean transportation is far more efficient in terms of transport capacity. Furthermore, many factories in Japan are located along the coast. Thus, I believe that it is well-fit with collecting marine biomass off the coast of Japan.
In Japan's case, aquaculture in the ocean is popular. The know-how about aquaculture for food can be converted into the implementation of carbon raw materials. Therefore, the Japanese government has been supporting marine biomass, by making blue carbon a catchy word. When it comes to food, many people have a negative impression of genetically modified seaweeds, such as wakame, kelp, and nori. I think that, if the aquaculture is intended to produce raw materials for carbon materials, the psychological barriers would be significantly lower. So, I believe genetic engineering could be used as well.

We would like JEOL to develop a measurement system that can be used commonly for different analytical instruments such as NMR spectrometers and electron microscopes. For example, a common sample holder for different instruments could be useful. This may be a bold request. I would like JEOL to develop it for the future where easier measurements from various angles are possible.

Jin Miyawaki, Associate Professor

Institute for Materials Chemistry and Engineering (IMCE), Kyushu Univ.

After completing the doctoral program (D.Sc.) at Graduate School of Science and Technology, Chiba University, he served as a postdoctoral researcher at the Energy Institute, Pennsylvania State University in the United States, a postdoctoral researcher at the Japan Science and Technology (JST), and an assistant professor at the Institute for Materials Chemistry and Engineering, Kyushu University. He has held the current position since 2013.