【DISCONTINUED】JAMP-9500F Field Emission Auger Microprobe

DISCONTINUED

JAMP-9500F Field Emission Auger Microprobe

This product is no longer available.

If you would like to know the latest information about your preferred product or to find out more about alternatives, please click on the link below. We hope you will continue to use our products.

It is a high specification Auger electron spectrometer with a hemispherical analyzer to provide high throughput analysis of the chemical bonding state at nano to micro areas, and a field emission electron gun also used for EPMA, because it can deliver a large, stable electric current The highly precise eucentric specimen stage makes it possible to perform the previously-impossible analysis of insulators. This in combination with the floating type ion gun offers the versatility to handle any specimen, such as metals and insulation materials, to obtain composition information to and chemical information.

Features

High-sensitivity・high-resolution analyzer

Employing analyzers with variable energy resolution has made it possible to perform chemical bonding state analysis in a high-resolution mode, as well as high-speed mapping in a high-sensitivity mode.

Schottky Field Emission Electron Gun

An electron gun that achieves both image observation with 3nm spatial resolution, as well as high-throughput chemical bonding state analysis as a result of the large electric current of up to 200nA. This is possible by incorporating the electron optics technology that JEOL has developed over many years with the Schottky Field Emission Electron Guns employed in SEMs and EMPAs.

Eucentric Specimen Stage

The adoption of an eucentric stage, a necessity for an analysis device with multiple optics systems, provides highly accurate height center reproducibility.  Freely-selectable tilting up to 90°makes difficult analysis of insulators possible.

Durability

Based on a long-life design concept, the running costs associated with the replacement of the ion gun filament and electron gun emitter have been reduced.

Software

Separation of overlapped Auger peaks, which aggravate analysts, as well as complicated chemical bonding state analysis can be performed with one click using the waveform separation function.
Map restructuring software enables a wide range of analyses, such as re-setting of P/B after measurement, and tracking the changes over time during integration.

Specifications

Electron illumination system
SEI resolution 3nm(at 25kV, 10pA)
Probe diameter for Auger analysis 8nm(at 25kV, 1nA)
Electron gun Schottky field emission gun
Accelerating voltage 0.5 to 30kV
Probe current 10-11 to 2×10-7A
Magnification x 25 to 500,000
Auger analysis system
Analyzer Electrostatic hemispherical  analyzer (HSA)
Energy resolution(ΔE/E) 0.05 to 0.6%
Sensitivity 840,000 cps/7 ch or more
(at 10 kV 10 nA Cu-LMN, 0.6% resolution, 60tilt)
Detection system Multi-channel detection
Ion gun
Ion energy 0.01 to 4keV
Ion current (absorbed current) 2 A or more at 3,000 eV, 0.03A or more at 10 eV
Neutralization function Built-in
Specimen stage
Specimen movement X: ±10 mm, Y: ±10 mm, Z: ±6 mm,
T (tilt): 0 to 90, R (rotation): 360(endless)
Specimen size 20 mm in diameter (5 mm thick)
UHV evacuation system
Ultimate pressure in specimen chamber 5×10-8Pa or less
Baking out Built-in heater, automatic baking out
Software
Data acquisition Spectrum,
Depth profile,
Line profile,
Auger image,
SEI (secondary electron image)
Wide area image analysis (optional),
Scheduling analysis (optional)
Data processing Qualitative analysis,
Quantitative analysis,
Differentiation,
Smoothing,
Image processing,
Text entering,
Peak deconvolution software (optional)
  • Specifications subject to change without notice.

Expandability

Additional ports to accommodate the following attachments are pro-vided, supporting a variety of analyses.
Large Specimen Stage (full observation for 95mm dia.disk)
Specimen Parking Unit
Specimen Cooling and Fracturing Device
Specimen Heating Device
Backscattered Electron Detector
Energy Dispersive X-ray Spectrometer (EDS)
Electron Backscatter Difraction Unit (EBSD)

Application

Application JAMP-9500F

More Info

JEOL Instrument Basics

Easy explanation about mechanisms and
applications of JEOL products

Close
Notice

Are you a medical professional or personnel engaged in medical care?

Yes

No

Please be reminded that these pages are not intended to provide the general public with information about the products.

Contacts

JEOL provides a variety of support services to ensure that our customers can use our products with peace of mind.
Please feel free to contact us.