Announcement of the JAM-5200EBMPlus Electron Beam Metal 3D Printer

Release Date: 2026/11/16

JEOL Ltd. (President & CEO Izumi Oi) announces the launch of the JAM-5200EBMPlus electron beam metal 3D printer on November 16, 2026.

Background of development

Metal additive manufacturing is increasingly being adopted for practical applications across the aerospace, automotive, energy, and medical device sectors. It has transitioned from  prototyping into a vital tool for manufacturing end-use parts and finished products. As adoption grows, production facilities increasingly require superior build quality, high productivity, and broader material compatibility, alongside tighter process management and quality assurance.

To meet these requirements, the JAM-5200EBMPlus offers a range of dedicated build units, each engineered to print specific metal materials. By optimizing the build environment for each material, the system delivers more consistent build quality and improved productivity.

The system introduces a new Multi-Dot Scanning feature, enabling a new melting strategy to the standard contour/hatch scan strategy typically used by powder bed fusion technologies. By optimizing the electron beam scanning process, it enhances process stability by fine-tuning the microstructure. The build quality is also improved across a wide range of metals, including surface quality, specifically in overhang regions.

In addition, BSE monitoring capabilities have been enhanced with In Situ Backscattered Electron Imaging (BSE), enabling real-time tracking of process conditions during the build cycle. This collected data simplifies quality confirmation and parameter optimization, streamlining both quality assurance and production management.

Together, these advancements deliver high-quality metal additive manufacturing and efficient production processes, providing robust support for a wide range of applications, from research and development to serial production.

Multi-Dot Scanning

BSE monitoring capabilities

Main features

  • Extended cathode service life and increased beam power output through an improved electron optical system

  • A lineup of dedicated build units tailored for print productivity of different metal materials

  • Multi-Dot Scanning feature for enhanced process stability and build quality

  • Enhanced process BSE monitoring capabilities using Backscattered Electron Imaging (optional)

Product Information

Electron Beam Metal 3D Printer JAM-5200EBMPlus