Release of the new gas chromatograph – time-of-flight mass spectrometer JMS-T2000GC AccuTOF™ GC-Alpha – the ultimate GC-MS with superior performance and ease of operation
Release Date: 2021/02/17
JEOL Ltd. (President & COO Izumi Oi) announces the release of JMS-T2000GC "AccuTOF™ GC-Alpha", the latest model of the successful AccuTOF™ GC series gas chromatograph – time-of-flight mass spectrometers, to be released in February 2021. This product is a GC-MS that represents a significant improvement in performance and functionality using two newly developed Key Technologies. The basic hardware performance has been greatly improved and a new generation of automated data analysis software is included in the standard configuration.
Main Features
Two new Key Technologies
- Key Technology 1: New high-performance hardware
The JMS-T2000GC "AccuTOF™ GC-Alpha", the 6th generation of the successful AccuTOF™ GC series, achieves three times the mass resolving power and mass measurement accuracy of the previous "AccuTOF™ GCx-plus" by using a whole new ion optics design that achieves excellent sensitivity and high data acquisition speed, the long-time hallmarks for the AccuTOF™ GC series. Additionally, the system has a wide dynamic range that is beneficial not only for quantitative analysis but also for qualitative analysis of complex mixtures.
A wide variety of ionization techniques – field ionization (FI), field desorption (FD), photoionization (PI), and chemical ionization (CI) – are optionally available, in addition to the standard electron ionization (EI). Two combination ion sources are also available as options – the EI/FI/FD combination ion source and the EI/PI combination ion source which allow easy switching between ionization techniques without breaking vacuum or replacing the ion sources. - Key Technology 2: A new generation of analysis software for simple, speedy operation (msFineAnalysis)
The msFineAnalysis software is a new generation of automated data analysis software that provides qualitative results by combining data acquired by EI and soft ionization (FI, CI, or PI) in a simple, speedy and automated way. This software makes full use of the high-quality data obtained by the JMS-T2000GC "AccuTOF™ GC-Alpha", thus providing a new approach to qualitative analysis for identification of unknown compounds.
The new two-sample comparison function provides Volcano Plots, which can visually illustrate the distinguishing components between the two samples. After determining whether there are differences, integrated analysis is performed for all components. The software also supports analysis of GC/EI data alone.

Annual unit sales target
50 units/year
LINK
Are you a medical professional or personnel engaged in medical care?
No
Please be reminded that these pages are not intended to provide the general public with information about the products.
