The JIB-4601F is a MultiBeam processing and observation system that incorporates a Schottky-type SEM and a High-Power FIB column. After performing cross-section milling of a region using FIB, it is possible to observe and analyze the internal portions using SEM. The FIB can be used for fine milling and TEM sample preparation, as well as performing 3-dimensional structure analysis with automatic cross-section milling/ observation & analysis at fixed intervals. The Schottky-type SEM enables easy positioning of the target site, as well as observation and analysis of minute structures. This is a system that can be used for a wide range of applications, including research & development as well as product quality control.
Features
All-in-one tool – Various applications offered by one instrument
Multi-function analysis through the combination of a High-Power FIB column and High-Power Optics SEM
The High-Power FIB column, with a maximum probe current of 60 nA, enables fast cross-section milling, while the Schottky SEM offers high-resolution observation of the cross-section. The High-Power Optics (maximum current 200 nA @ 15 kV) that are incorporated in the SEM make it possible to perform high-speed, high-resolution analyses, such as element analysis using EDS or WDS, and EBSD crystal orientation analysis. In addition, there is a full range of optional attachments available, including transmission electron detectors, specimen cooling mechanisms like a cryo unit and cool stage, and cathodoluminescence detectors.
3-dimensional structure analysis function
By automatically alternating between FIB section milling using the serial slicing and sampling function, and SEM observation and analysis (EDS mapping or EBSD crystalline structure analysis) it is possible to analyze the 3-dimensional structure of a specimen. The measurements can be performed rapidly because there is no need to shift the specimen stage.
Compatible with other JEOL products
Specifications
Electron gun | Schottky Field Emission Type △TFE(ZrO/W) |
---|---|
Objective lens | Out-lens type objective lens |
Resolution | 1.2 nm @ 30 kV WD4mm 3.0 nm @ 1 kV WD2mm |
Accelerting Voltage | 0.2 to 30kV |
Probe current | Several pA to 200nA @ 15 kV |
Aperture angle optimizing lens | Built-in |
Magnification | x20 to x1,000,000 |
Detectors | Lower Electron Detector(LED) Option(*) R-BED* STEM* |
Gentle beam | Built-in (Voltage applied to specimen 0 to 300V) |
Specimen exchange chamber | Built-in (with dry nitrogen introduction function) |
Specimen stage | 6-axis motor drive stage |
Specimen travel range | X: 50 mm , Y: 50 mm, Z: 1.5 to 41 mm Tilt: -5 to 70°, Roration: 360°, Fz: -3 to +3mm |
Specimen exchange method | One-touch chucking type |
Specimen holder | Standard Holder : φ12.5 holder φ32mm holder Option holder : 76.2mm wafer holder 100mm wafer holder 125mm wafer holder 150mm wafer holder 2,4,6 type bulk holder Surface multi-specimen holder STEM holder Shuttle retainer holder One-touch holder |
Chamber scope | Specimen Chamber Camera (option) |
Auto functions | Auto focus Auto brightness control |
System control | SEM controlling system PC IBM PC/AT compatible〔SM-77360PC〕 RAM 2 GB or more OS Windows 7® Professional* |
Monitor | 23 inch |
Image display | Image display area 1280×960 pixel, 800×600 pixel |
Display modes | Standard : SEM_SEI, FIB_SEI Option : SEM_COMPO, SEM_TOPO, AUX, CCD |
Scanning / Display modes | Limited area scanning, addition iamge, scaler Screen display: 1 screen, 2 screen(standard), 4 screen |
Vacuum | HV ; < 2.0 x 10E-4 Pa (when GIS is in use;<3.0E-3Pa) |
Evacuation system | SIP x 2 (SEM), SIP x 1 (FIB), TMP x 1, v RP x 1 |
Electricity consumption saving mode | In normal operation approx. 2.0kVA |
Co2emission equivalent | Co2 emission in year Normal operation 4967kg |
Safety device | Protection against vacuum fall, water failure, N2 gas pressure fall, leakage current However, ultra high vacuum maintenance mechanism at power failure is not included. |
Footprint | 3200mm or more ×3000mm or more |
Installation Requirement |
Power Supply Single PHase 100 V, 50/60 Hz, max. 4kVA, Normal use approx. 2.0kVA Allowable input power supply fluctuation within ±10% Grounding terminal 100Ω or less x 1 Cooling water Faucet out. dia. 14 mm x 1, or JIS B 0203 Rc 1/4 x 1 Flow rate 0.5 L/min Water pressure 0.1to 0.25 MPa (gauge pressure) Water temperature 20°± 5℃ Drain inn. dia. 25 mm or more x1, or JIS B 0203 Rc 1/4 x 1 Dry nitrogen gas JIS B 0203 Rc 1/4(to be provided by user) Pressure 0.45 to 0.55 MPa (gauge pressure) Installation Room Room temperature 20℃±5℃ Humidity 60% or lower Stray magnetic field 0.3μT (P-P) or less (50/60 Hz sin wave,WD 10 mm,15 kV)*1 Floor vibration 3μm (P-P) or lower*1 at frequency of sin wave more than 5Hz. Noise 70 dB or lower *1 as FLAT characteristic Dimension of installation room 3,000 mm x 3,000 mm or more Height 2,300 mm or higher Door size 1,000*2 mm(w) x 2,000 mm(H) or more
|
Main optional attachments | EDS, WDS, EBSD, CL, SNS etc. |
Windows is a registered trademark of Microsoft Corporation in the United States and other countries.