JSM-6610 Series Scanning Electron Microscope
DISCONTINUED
Seamless transition between imaging and analysis. A general-purpose, thermal type SEM to meet the needs of a wide range of users, as standard recipes simplify the setting procedures. The standard 5-axis motor stage makes it easy to locate the area of interest.
Features
Operation navigation
The operation navigation screen displays a variety of navigation functions.
The specimen exchange procedure is presented in a flow format, so that the process can be easily completed even by a first time user.
A stage graphic simplifies the search for target sites
When the stage navigation system (option) is used, it is possible to locate a region of interest with the feel of operating an optical microscope.
Video animations supplement the maintenance procedure explanations
Standard recipes
Standard recipes incorporating JEOL expertise and experience are pre-installed
Even new SEM users can set conditions suitable for each sample
Large stage
A large specimen chamber with a 5-axis motor-driven stage is included in the standard configuration
Samples as large as 8-inch diameter x 80 mm height can be handled
EDS integration
Analysis can be started from the SEM window
Since the EDS is also a JEOL product, control can be performed from a single PC
Specifications
ResolutionHV mode | 3.0 nm(30 kV)、8 nm(3 kV)、15 nm(1 kV) |
---|---|
LV mode *1 | 4.0 nm(30 kV) |
magniἀcations | × 5 to × 300,000 (on 128 mm × 96 mm image size) |
Preset magnifications | 5 step, user selectable |
Standard recipe | Built in |
Custom recipe | Operation conditions (Optics, Image mode, LV pressure*1) Specimen stage |
Image mode | Secondary electron image, REF image, Composition*1, Topography*1, Shadowed*1 |
Accelerating voltage | 0.3 kV to 30 kV |
Filament | Factory pre-centered filament |
Electron gun | Fully automated, manual override |
Condenser lens | Zoom condenser lens |
Objective lens | Super conical objective lens |
Objective lens apertures | 3 stages, XY fine adjustable |
Stigmator memory | Built in |
Electrical image shift | ± 50 μm (WD = 10 mm) |
Auto functions | Focus, brightness, contrast, stigmator |
Specimen stage | Eucentric large-specimen stage
axes motorized X: 125 mm, Y: 100 mm, Z: 5 mm to 80 mm, Tilt: −10° to 90°, Rotation: 360° |
Reference image (Navigator) | 4 images |
Specimen exchange | Draw out the stage |
Maximum specimen | 200 mm diameter |
PC | IBM PC/AT compatible |
OS | Windows 7 |
Monitor | 19 inch LCD, 1 or 2*2 |
Frame store | 640 × 480, 1,280 × 960, 2,560 × 1,920, 5,120 × 3,340 |
Dual live image | Built in |
Full size image display | Built in |
Pseudo color | Built in |
Multi image display | 2 images, 4 images |
Digital zoom | Built in |
Dual magniἀcation | Built in |
Network | Ethernet |
Measurement | Built in |
Image format | BMP、TIFF、JPEG |
Auto image archiving | Built in |
Pumping system | Fully automated, DP: 1, RP: 1 or 2*1 |
Switching vacuum mode*1 | Through the menu, less than 1 minute |
LV Pressure*1 | 10 to 270 Pa |
JED-2300 EDS*2 | Built in |
Principal Options
Backscattered electron detector*1
Low vacuum secondary electron detector
Energy dispersive X-ray analyzer (EDS)
Wave length dispersive X-ray analyzer (WDS)
EBSD
Stage navigation system
Airlock chamber
Chamber scope
Operation keyboard
LaB6 electron gun
Report creation software (SMile View™)*2
Operation console (750 mm wide, 900 mm wide)
Standard on JSM-6610LA and JSM-6610LV
Standard on JSM-6610LA and JSM-6610A
Application
Application JSM-6610series
High Angle Backscattered Electrons and Low Angle Backscattered Electrons
Introducing the ALTO Series (Cryo System)
Gallery
More Info